NA2XY 0,6/1 kV 300 mm2
NA2XY 0,6/1 kV 300 mm2
Aplicación general como cable de energía en baja tensión, en instalaciones fijas.
Lee más- Nexans ref. : P00035518-0
Descripción
Descripción
Estándares
-
InternacionalIEC 60228; IEC 60332-1-2; IEC 60502-1; IEC 60754-1; UIC 895
-
NacionalNTP-IEC 60228; NTP-IEC 60502-1; SAE J-1127; UL 2556; UL 44
Application:
General application as power cable. In low voltage distribution power networks, industrial installations, in buildings and operation stations. In fixed installations, indoor and outdoor areas (trays, gutters, staples). It can be installed in ducts, in dry or wet locations.
Construction:
1. Conductor: Compacted round Aluminium 1350, class 2.
2. Insulation: Cross linked polyethylene XLPE.
3. Outer sheath: Anti-flame compound polyvinyl chloride PVC.
Voltage:
CA 0,6/1 kV (1,2 kV)
CC 1,5/1,5 kV (1,8 kV)
Main characteristics:
Excellent properties against heat aging. Resistance to abrasion, moisture and sunlight. Resistance to liquid fuels and oils according to UIC 895 OR. Resistance to sulfuric acid according to SAE J1127. Low halogen content according to IEC 60754-1. Resistant to gasoline GR I according to UL 44.
Gauge:
300 mm2.
Marking:
INDECO S.A. NA2XY 0,6/1 kV Section - Year - Sequential length.
Packing:
Non returnable wooden reels.
Colour:
Insulation: Natural.
Outer sheath: Black.
National standards
NTP-IEC 60228: Conductors of insulated cables.
NTP-IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV and 3 kV.
International standards
IEC 60228: Conductors of insulated cables.
IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV and 3 kV.
IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.
UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.
IEC 60754-1: Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content.
SAE J1127: Standard for Vehicle Cables. Battery cable Clause 6.7 (Compatibility of fluids) - Resistance to Sulfuric Acid.
UL 44: Thermoset-Insulated Wires and Cables. Section 5.17: Gasoline and oil resistance.
UIC 895 OR: Technical specifications for the supply of insulated electric cables for railway vehicles - Oil resistance.
UL 2556: Wire and Cable Test Methods. Section 4.2.8.5:Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.
RADIO DE CURVATURA UNA VEZ INSTALADO EN B.T.
R=Dxf
R: Radio de curvatura una vez instalado (mm)
D: Diámetro sobre cubierta externa o sobre aislamiento (cuando no tiene cubierta externa) (mm)
f: Factor multiplicativo; dado en la siguiente tabla:
Factor del Radio de Curvatura BT
Condiciones de Cálculo de Corriente: Conductor de Aluminio Unipolar L.V.; 90°C
VALORES DE CAPACIDAD DE CORRIENTE Y CONDICIONES DE CALCULO DE CORRIENTE BASADOS EN IEC 60364-5-52:2009 :
TABLA B.52.5 (METODO D2: Enterrado en formación triangular).
TABLA B.52.13 (METODO F: Al aire en formación plana y en contacto).
TABLA B.52.13 (METODO F: Al aire en formación triangular).
Temperatura máxima del conductor : 90°C.
Temperatura ambiente : 30°C.
Temperatura del terreno : 20°C.
Profundidad de tendido hasta : 0,7 m.
Resistividad térmica del terreno : 2,5 K.m/W.
Características
Características
Características de construcción
Características de construcción
Características dimensionales
Características dimensionales
Características eléctricas
Características eléctricas
Características mecánicas
Características mecánicas
Características de uso
Características de uso
Recursos
Recursos
Nuestros sitios web
Selecciona tu país para conocer nuestros productos y soluciones
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania