N2XSEYRY 12/20 kV; for installation in vertical drilling mines

Products

N2XSEYRY 12/20 kV 3x95 mm2

Nexans ref. P00032884-1

  • Conductor diameter: 11.5 mm
  • Diameter over Sheath: 68.3 mm
  • Approximate weight: 8643 kg/km

 

N2XSEYRY 12/20 kV 3x95 mm2

Nexans ref. P00028119-0

  • Conductor diameter: 11.5 mm
  • Diameter over Sheath: 68.3 mm
  • Approximate weight: 8897 kg/km

 

N2XSEYRY 12/20 kV 3x50 mm2

Nexans ref. P00033383-0

  • Conductor diameter: 8.2 mm
  • Diameter over Sheath: 64.3 mm
  • Approximate weight: 9404 kg/km

 

N2XSEYRY 12/20 kV 3x120 mm2

Nexans ref. P00036850-0

  • Packaging: Cut to length (m)
  • Conductor diameter: 13.0 mm
  • Diameter over Sheath: 79.8 mm
  • Approximate weight: 13179 kg/km

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60332-1-2; IEC 60502-2; IEC 60811-401; IEC 60811-402; IEC 60811-409; IEC 60811-501; IEC 60811-502; IEC 60811-504; IEC 60811-505; IEC 60811-506; IEC 60811-507; IEC 60811-508; IEC 60811-509
  • National
    ICEA S-93-639; NTP-IEC 60228; NTP-IEC 60502-2; UL 2556

Application:

Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations, where mechanical strength is required, for instalation in vertical drilling mines.

Construction:

1. Conductor: Compact stranded soft copper, class 2.

2. Inner semi-conductor: Extruded.

3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).

4. External semi-conductor: Extruded strippable.

These last three components extruded CV (continuous vulcanization) triple extrusion in Dry cure process.

5. Screen: Copper tapes.

6. Separation sheath: Compound polyvinyl chloride PVC.

7. Armour: Galvanized steel wires.

8. Tape: Polyester tape.

9. Outer sheath: Compound polyvinyl chloride PVC.

Main characteristics:

Excellent properties against heat aging. Its armour provides additional mechanical protection. Resistance to abrasion, moisture and sunlight. Adequate resitance to greases and oils. Flame retardant.

Cross section:

From 50 mm2 up to 120 mm2.

Marking:

INDECO S.A. N2XSEYRY 12/20 kV - Nb. Cores x Section - Year - Sequential length.

Packing:

Non returnable wooden reels.

Colour:

Insulation: Natural (Core identification with binder tapes: white, black, red).

Outer sheath: Red.

National standards

NTP-IEC 60228: Conductors of insulated cables.

NTP-IEC 60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV.

International standards

IEC 60228: Conductors of insulated cables.

IEC 60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV.

IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.

UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.

IEC 60811-401: Thermal ageing methods. Ageing in an air oven.

IEC 60811-402: Water absorption tests.

IEC 60811-409: Loss of mass test for thermoplastic insulations and sheaths.

IEC 60811-501: Test for determining the mechanical properties.

IEC 60811-502: Shrinkage test for insulations.

IEC 60811-504: Bending test at low temperature for insulation and sheaths.

IEC 60811-505: Elongation at low temperature for insulations and sheaths.

IEC 60811-506: Impact test at low temperature for insulations and sheaths.

IEC 60811-507: Hot set test for cross-linked materials.

IEC 60811-508: Pressure test at high temperature for insulation and sheaths.

IEC 60811-509: Test for resistance of insulations and sheaths to cracking.

ICEA S-93-639: 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy. Section 9.4.2: Oil Immersion Test.

UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.

CONDITIONS FOR INSTALLATION IN MINE SHAFTS M.T.

BENDING RADIUS INSTALLED IN M.V

R=Dxf

R:  Bending radius when installed (mm)

D:  Diameter over sheath (mm)

f:   Multiplicative factor; given the following table:

 

Bending radius factor MV

Calculation of Current Condition Multi-core M.V.

CALCULATION OF CURRENT CONDITION BASED ON NTP-IEC 60502-2 Annex B

Maximum conductor temperature: 90°C.
Ambient air temperature: 30°C.
Ground temperature: 20°C.
Depth of laying: 0,8 m.
Thermal resistivity of soil: 1,5 K.m/W.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Material of the inner semi-conductor
Extruded
Insulating material
XLPE-TR
Material of the external semi-conductor
Extruded strippable
Individual screen
Copper tapes helically applied
Armour type
Galvanized steel wires
Outer sheath
PVC
Sheath colour
Red
Lead free
Yes
Conductor flexibility
Class 2 IEC 60228
Conductor shape
Compact stranded

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
12 / 20 (24) kV
Dielectric strength core to screen AC
42.0 kV
Time of application Dielectric strength core to screen AC
5 min.
Voltage for partial discharge test
20.8 kV
Maximal partial discharge test
10 pC
Impulse voltage
125 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2; FT1
Oil resistance
ICEA S-93-639
U.V resistance
UL 2556 - Sunlight Resistance
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close