- Markets
- Catalogue
- Services
- Tools & Resources
- Downloads
- About Nexans
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- Guide to Prevent Fires and Accidents at Home (only in Spanish)
- Ten technologies to electrify the future: Electrical and Fire Safety
- Big data & AI
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- The path to effective fire safety in buildings
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Search
- Contact us
- Compare
- Sign in
N2XSEYRY 12/20 kV; for installation in vertical drilling mines
N2XSEYRY 12/20 kV; for installation in vertical drilling mines
Cable for underground power distribution and subtransmission.
Read moreN2XSEYRY 12/20 kV 3x95 mm2
Nexans ref. P00032884-1
- Conductor diameter: 11.5 mm
- Diameter over Sheath: 68.3 mm
- Approximate weight: 8643 kg/km
N2XSEYRY 12/20 kV 3x95 mm2
Nexans ref. P00028119-0
- Conductor diameter: 11.5 mm
- Diameter over Sheath: 68.3 mm
- Approximate weight: 8897 kg/km
N2XSEYRY 12/20 kV 3x50 mm2
Nexans ref. P00033383-0
- Conductor diameter: 8.2 mm
- Diameter over Sheath: 64.3 mm
- Approximate weight: 9404 kg/km
N2XSEYRY 12/20 kV 3x120 mm2
Nexans ref. P00036850-0
- Packaging: Cut to length (m)
- Conductor diameter: 13.0 mm
- Diameter over Sheath: 79.8 mm
- Approximate weight: 13179 kg/km
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-2; IEC 60811-401; IEC 60811-402; IEC 60811-409; IEC 60811-501; IEC 60811-502; IEC 60811-504; IEC 60811-505; IEC 60811-506; IEC 60811-507; IEC 60811-508; IEC 60811-509
-
NationalICEA S-93-639; NTP-IEC 60228; NTP-IEC 60502-2; UL 2556
Application:
Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations, where mechanical strength is required, for instalation in vertical drilling mines.
Construction:
1. Conductor: Compact stranded soft copper, class 2.
2. Inner semi-conductor: Extruded.
3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).
4. External semi-conductor: Extruded strippable.
These last three components extruded CV (continuous vulcanization) triple extrusion in Dry cure process.
5. Screen: Copper tapes.
6. Separation sheath: Compound polyvinyl chloride PVC.
7. Armour: Galvanized steel wires.
8. Tape: Polyester tape.
9. Outer sheath: Compound polyvinyl chloride PVC.
Main characteristics:
Excellent properties against heat aging. Its armour provides additional mechanical protection. Resistance to abrasion, moisture and sunlight. Adequate resitance to greases and oils. Flame retardant.
Cross section:
From 50 mm2 up to 120 mm2.
Marking:
INDECO S.A. N2XSEYRY 12/20 kV - Nb. Cores x Section - Year - Sequential length.
Packing:
Non returnable wooden reels.
Colour:
Insulation: Natural (Core identification with binder tapes: white, black, red).
Outer sheath: Red.
National standards
NTP-IEC 60228: Conductors of insulated cables.
NTP-IEC 60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV.
International standards
IEC 60228: Conductors of insulated cables.
IEC 60502-2: Power cables with extruded insulation and their accessories for rated voltages from 6 kV up to 30 kV.
IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.
UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.
IEC 60811-401: Thermal ageing methods. Ageing in an air oven.
IEC 60811-402: Water absorption tests.
IEC 60811-409: Loss of mass test for thermoplastic insulations and sheaths.
IEC 60811-501: Test for determining the mechanical properties.
IEC 60811-502: Shrinkage test for insulations.
IEC 60811-504: Bending test at low temperature for insulation and sheaths.
IEC 60811-505: Elongation at low temperature for insulations and sheaths.
IEC 60811-506: Impact test at low temperature for insulations and sheaths.
IEC 60811-507: Hot set test for cross-linked materials.
IEC 60811-508: Pressure test at high temperature for insulation and sheaths.
IEC 60811-509: Test for resistance of insulations and sheaths to cracking.
ICEA S-93-639: 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy. Section 9.4.2: Oil Immersion Test.
UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.
CONDITIONS FOR INSTALLATION IN MINE SHAFTS M.T.
BENDING RADIUS INSTALLED IN M.V
R=Dxf
R: Bending radius when installed (mm)
D: Diameter over sheath (mm)
f: Multiplicative factor; given the following table:
Bending radius factor MV
Calculation of Current Condition Multi-core M.V.
CALCULATION OF CURRENT CONDITION BASED ON NTP-IEC 60502-2 Annex B
Maximum conductor temperature: 90°C.
Ambient air temperature: 30°C.
Ground temperature: 20°C.
Depth of laying: 0,8 m.
Thermal resistivity of soil: 1,5 K.m/W.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania