CAAI 0,6/1 kV AAAC Covered Neutral with Public Lighting; GSC009 Rev.1
CAAI 0,6/1 kV AAAC Covered Neutral with Public Lighting; GSC009 Rev.1
For overhead secundary distribution networks.
Read moreCAAI 0,6/1 kV 3x35+2x16+NA54,6 mm2
Nexans ref. P00025012-8
- Packaging: Cut to length (m)
- Phase Conductor Diameter: 6.9 mm
- Nominal outer diameter: 27.6 mm
- Approximate weight: 772 kg/km
- Perm current rating in air 40°C: 119 A
CAAI 0,6/1 kV 3x95+2x16+NA54,6 mm2
Nexans ref. P00025011-8
- Phase Conductor Diameter: 11.4 mm
- Nominal outer diameter: 41.9 mm
- Approximate weight: 1356 kg/km
- Perm current rating in air 40°C: 226 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60811-201; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-502; IEC 60811-507; IEC 60811-511
-
NationalGSCC009; NTP-IEC 60228
Application:
For urban and rural overhead secundary distribution networks, with voltages up to 1000 V.
Construction:
1. Conductor: Aluminium 1350, class 2.
2. Insulation: Cross linked polyethylene XLPE.
3. Public lighting: Aluminium 1350 insulated with cross-linked polyethylene XLPE.
4. Insulated neutral messenger: AAAC - All Alloy Aluminium AL2 (EN 50183) - XLPE.
Main characteristics:
Decreases energy theft, cross-linked polyethylene allows more current capacity and high insulation resistance, lower inductive reactance than with bare conductors, used in overhead distribution lines. Increased safety due to its mechanical strength and toughness of the insulation. Insulators are not necessary for installation. Resistance to abrasion, weather and sunlight.
Cross section:
35 mm2 and 95 mm2.
Marking:
ENEL DISTRIBUCION PERU - INDECO S.A.- AL-XLPE-0,6/1(1,2) kV - (Nb. Cores x Section) + (Nb. conductors x public lighting section) + AAAC(1xNeutral messenger section) - Year - Month - Sequential length.
Packing:
Non returnable wooden reels.
Colour:
Black, see core identification.
National standards
NTP-IEC 60228: Conductors of insulated cables.
International standards
IEC 60228: Conductors of insulated cables.
GSC009-1: Overhead low voltage distribution cables with rated voltage Uo/U(Umax)= 0,6/1 (1,2) kV.
IEC 60811-201: Measurement of insulation thickness.
IEC 60811-401: Thermal ageing methods -Ageing in an air oven.
IEC 60811-402: Water absorption test.
IEC 60811-501: Test for determining the mechanical properties of insulating and sheating.
IEC 60811-502: Shrinkage test for isolations.
IEC 60811-507: Hot elongation test for crosslinked materials.
IEC 60811-511: Measurement of hot melt index of polyethylene compounds.
BENDING RADIUS WHEN INSTALLED
R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).
Calculation of Current Condition overhead secondary distribution CAAI; GSC009 Rev.1
CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 8182
Maximum conductor temperature : 90°C.
Ambient air temperature : 40°C.
Speed of cross wind: Nula
Intensity of solar radiation: 1000 W/m2
Bundled conductors.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania