CAAI 0,6/1 kV AAAC Covered Neutral with Public Lighting; GSC009 Rev.1

Products

CAAI 0,6/1 kV 3x35+2x16+NA54,6 mm2

Nexans ref. P00025012-8

  • Packaging: Cut to length (m)
  • Phase Conductor Diameter: 6.9 mm
  • Nominal outer diameter: 27.6 mm
  • Approximate weight: 772 kg/km
  • Perm current rating in air 40°C: 119 A

 

CAAI 0,6/1 kV 3x95+2x16+NA54,6 mm2

Nexans ref. P00025011-8

  • Phase Conductor Diameter: 11.4 mm
  • Nominal outer diameter: 41.9 mm
  • Approximate weight: 1356 kg/km
  • Perm current rating in air 40°C: 226 A

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60811-201; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-502; IEC 60811-507; IEC 60811-511
  • National
    GSCC009; NTP-IEC 60228

Application:

For urban and rural overhead secundary distribution networks, with voltages up to 1000 V.

Construction:

1. Conductor: Aluminium 1350, class 2.

2. Insulation: Cross linked polyethylene XLPE.

3. Public lighting: Aluminium 1350 insulated with cross-linked polyethylene XLPE.

4. Insulated neutral messenger: AAAC - All Alloy Aluminium AL2 (EN 50183) - XLPE.

Main characteristics:

Decreases energy theft, cross-linked polyethylene allows more current capacity and high insulation resistance, lower inductive reactance than with bare conductors, used in overhead distribution lines. Increased safety due to its mechanical strength and toughness of the insulation. Insulators are not necessary for installation. Resistance to abrasion, weather and sunlight.

Cross section:

35 mm2 and 95 mm2.

Marking:

ENEL DISTRIBUCION PERU - INDECO S.A.- AL-XLPE-0,6/1(1,2) kV - (Nb. Cores x Section) + (Nb. conductors x public lighting section) + AAAC(1xNeutral messenger section) - Year - Month - Sequential length.

Packing:

Non returnable wooden reels.

Colour:

Black, see core identification.

National standards

NTP-IEC 60228: Conductors of insulated cables.

International standards

IEC 60228: Conductors of insulated cables.

GSC009-1: Overhead low voltage distribution cables with rated voltage Uo/U(Umax)= 0,6/1 (1,2) kV.

IEC 60811-201: Measurement of insulation thickness.

IEC 60811-401: Thermal ageing methods -Ageing in an air oven.

IEC 60811-402: Water absorption test.

IEC 60811-501: Test for determining the mechanical properties of insulating and sheating.

IEC 60811-502: Shrinkage test for isolations.

IEC 60811-507: Hot elongation test for crosslinked materials.

IEC 60811-511: Measurement of hot melt index of polyethylene compounds.

BENDING RADIUS WHEN INSTALLED

R = f x D
R: Bending radius when installed (mm).
f: Multiplicative factor.
D: Cable nominal outer diameter (mm).

Calculation of Current Condition overhead secondary distribution CAAI; GSC009 Rev.1

CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 8182

Maximum conductor temperature : 90°C.
Ambient air temperature : 40°C.
Speed of cross wind: Nula
Intensity of solar radiation: 1000 W/m2
Bundled conductors.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum Alloy 1350
Insulating material
XLPE
Core identification
Rib markings
Neutral messenger
Alloy Aluminium
Conductor flexibility
Class 2 IEC 60228
Conductor shape
Compact stranded

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Dielectric strength
4.0 kV
Time of application Dielectric strength core to screen DC
15 min.

Usage characteristics

Usage characteristics

Bending factor when installed
4 (xD)
U.V resistance
Yes
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close