- Markets
- Catalogue
- Services
- Tools & Resources
- Downloads
- Company
- Newsroom
-
Nexans Insights
- Nexans Insights
-
Blog Posts
- Overview
- Growing demand for copper and its future
- Electromobility: the road to building an increasingly sustainable transport system
- Guide to Prevent Fires and Accidents at Home (only in Spanish)
- Ten technologies to electrify the future: Electrical and Fire Safety
- Big data & AI
- IoT
- Unveiling innovations transforming the industry
- Transforming buildings industry with 3D printing and modular construction
- The path to effective fire safety in buildings
- Powering the digital change
- Unleashing the power of DC buildings
- Sustainable buildings for a brighter future
- Industry 1, 2, 3, 4... and 5.0
- Nexans copper odyssey
- Limitations of aluminium as an electrical conductor in residential installations
- Find Distributors
- Search
- Contact us
- Compare
- Sign in
NA2XS2Y(OL) 19/33 kV PH; Outer sheath HDPE; UV Resist; IRAM 2178
NA2XS2Y(OL) 19/33 kV 400 mm2 PH16
Nexans ref. P00050879-0 - Country ref. 10056510
- Packaging: Cut to length (m)
NA2XS2Y(OL) 19/33 kV 630 mm2 PH16
Nexans ref. P00050880-0 - Country ref. 10056511
- Packaging: Cut to length (m)
NA2XS2Y(OL) 19/33 kV 95 mm2 PH16
Nexans ref. P00050878-0 - Country ref. 10056509
- Packaging: Cut to length (m)
Description
Description
Application
Power distribution in medium voltage. As transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations.
CONSTRUCTION
1. Conductor: Compact stranded aluminium 1350, class 2 (longitudinally watertight inside the conductor).
2. Inner semi-conductor: Extruded.
3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).
4. External semi-conductor: Extruded strippable.
These last three components extruded CV (continuous vulcanization) triple extrusion in dry cure process.
5. Screen: Copper wires (longitudinally watertight under and over the screen).
6. Outer sheath: HDPE High density polyethylene.
MAIN CHARACTERISTICS
Excellent properties against heat aging. Longitudinally watertight inside the conductor; and under and over screen. The outer sheath has the following characteristics: resistance to abrasion and moisture. Adequate resistance to greases and oils. Low emission dense smoke and halogen free.
GAUGE
150 mm2
MARKING
INDECO BY NEXANS NA2XS2Y(OL) 19/33 kV - Section - PH (Screen section) - Year - Sequential length.
PACKING
Non returnable wooden reels.
COLOUR
Insulation: Natural.
Outer sheath: Black.
PRODUCT STANDARDS
NTP-IEC 60228: Conductors of insulated cables.
IEC 60228:Conductors of insulated cables.
IRAM 2178-2: Isolated Power Cables with Dielectric Solid Extruded for nominal voltages from 1,1 kV to 33 kV. Part 2: Power cables for nominal voltages from 3,3 kV (3,6 kV) to 33 kV (36 kV).
TESTING STANDARDS
IEC 60754-1: Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content.
IEC 60754-2: Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity.
ICEA S-93-639:5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy - Section 9.4.2: Oil Immersion Test.
UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance. Section 9.3: FT1 (Vertical-Specimen) Flame Test.
Calculation of Current Condition Single core Medium Voltage
CALCULATION OF CURRENT CONDITION BASED ON ABNT NBR 14039
Maximum conductor temperature: 90°C.
Ambient air temperature: 30°C.
Ground temperature: 20°C.
Depth of laying: 0,9 m.
Thermal resistivity of soil: 1,5 K.m/W.
Thermal resistivity of duct: 1,2 K.m/W.
RECOMMENDATION - M.V. CABLE ACCESSORIES
Technical information presented herein is for referential purposes. Actual dimensions and construction details will be available only with the test reports for each manufacturing order. For "Make To Stock" products it is recommended to measure relevant dimensions directly on the cable. Nexans will not assume responsibility for connector selection.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania