XLPE/S; ICEA S-93-639 - RETIE

Description

Description

Application

Power distribution in medium voltage. As transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations.

CONSTRUCTION

1. Conductor: Compact stranded aluminium 1350, class B (longitudinally watertight between core conductor).

2. Inner semi-conductor: Extruded.

3. Insulation: Cross linked polyethylene XLPE-TR (Tree retardant).

4. External semi-conductor: Extruded strippable.

These last three components extruded CV (continuous vulcanization) triple extrusion in dry cure process.

5. Concentric conductor: Copper wires helically applied. Concentric neutral according to ICEA S-94-649 (longitudinally watertight under and over concentric conductor).

6. Outer sheath: HDPE High density polyethylene.

MAIN CHARACTERISTICS

Excellent properties against heat aging. Longitudinally watertight between core conductor; and under and over concentric conductor. Resistance to abrasion, moisture and sunlight. Adequate resistance to greases and oils. Flame retardant.

GAUGE

From 3/0 AWG up to 1250 kcmil.

MARKING

INDECO BY NEXANS NA2XC2Y(2OL) 35 kV - Gauge - NC(Number) - Year - Sequential length.

PACKING

Non returnable wooden reels.

COLOUR

Insulation: Natural.

Outer sheath: Black.

PRODUCT STANDARDS

ASTM B231: Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors.

ICEA S-94-649: Concentric Neutral Cables Rated 5 Through 46 kV.

TESTING STANDARDS

IEC 60754-1: Test on gases evolved during combustion of materials from cables. Part 1: Determination of the halogen acid gas content.

IEC 60754-2: Test on gases evolved during combustion of materials from cables. Part 2: Determination of acidity (by pH measurement) and conductivity.

IEC 61034-2: Measurement of smoke density of cables burning under defined conditions.

ICEA S-93-639: 5-46 kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy. Section 9.4.2: Oil Immersion Test.

UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance.

ICEA T-34-664: Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables.

Calculation of Current Condition: Copper conductor Single-core AWG/kcmil M.V.; 90°C

CURRENT CAPACITY VALUES AND CURRENT CALCULATION CONDITIONS BASED ON NEC 2023:

TABLE 315.60(C)(3) (Air in flat formation)
TABLE 315.60(C)(1) (Air in tringular formation)
TABLE 315.60(C)(15) (Directly buried in flat formation)
TABLE 315.60(C)(19) (Directly buried in tringular formation)
TABLE315.60(C)(11) (Buried duct)

Horizontal flat formation clearance: 190 mm.
Maximum conductor temperature: 90°C.
Ambient air temperature: 40°C.
Ground temperature: 20°C.
Depth of laying: 0,9 m.
Thermal resistance: 0,9 K.m/W.

Calculation of Current Condition: Aluminium conductor Single-core AWG/kcmil M.V.; 90°C

CURRENT CAPACITY VALUES AND CURRENT CALCULATION CONDITIONS BASED ON NEC 2023:

TABLE 315.60(C)(4) (Air in flat formation)
TABLE 315.60(C)(2) (Air in tringular formation)
TABLE 315.60(C)(16) (Directly buried in flat formation)
TABLE 315.60(C)(20) (Directly buried in tringular formation)

Horizontal flat formation clearance: 190 mm.
Maximum conductor temperature: 90°C.
Ambient air temperature: 40°C.
Ground temperature: 20°C.
Depth of laying: 0,9 m.
Thermal resistance: 0,9 K.m/W.

RECOMMENDATION - M.V. CABLE ACCESSORIES

Technical information presented herein is for referential purposes. Actual dimensions and construction details will be available only with the test reports for each manufacturing order. For "Make To Stock" products it is recommended to measure relevant dimensions directly on the cable. Nexans will not assume responsibility for connector selection.

PE sheathed cables

Consider Low Smoke Density characteristic of IEC 61034-2 only for cables with Red jacket.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Material of the inner semi-conductor
Extruded
Insulating material
XLPE-TR
Material of the external semi-conductor
Extruded strippable
Conductor flexibility
Class B

Usage characteristics

Usage characteristics

Oil resistance
ICEA S-93-639
Maximum operating temperature
90 °C
Overload maximum core temperature
130 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close